Description
Resistance temperature sensor. Suitable for hazardous area use.
The thermometers can be used in process industries such as:
- Chemical industry
- Energy industry
- Gas processing industry
- Petrochemical industry
The Omnigrad S is an industrial RTD thermometer with a (Pt100) inset and thermowell. It complies with EN 50014/18/20 (ATEX certification) and is therefore suitable for use in hazardous areas. Omnigrad S RTDs are available with PCP, HART, PROFIBUS PA or FOUNDATION Fieldbus electronics and a variety of connections including threaded, flanged and compression fittings.
Technical Data
Version | TR61 | TR62 | TR63 |
Certification | ATEX EEx ia
ATEX EEx d |
ATEX EEx ia
ATEX EEx d |
ATEX EEx ia
ATEX EEx d |
Process connections | Compression fitting, thread (NPT/G) or flange (ANSI/DIN) | Thermowell thread: ½”NPT | Compression fitting, thread (NPT/G) or flange (ANSI/DIN) |
Sensor element diameter | 3mm, 6mm | 6mm | 3mm, 6mm |
Response times (straight tip) | 6mm
t50 = 18s t90 = 55s |
6mm
t50 = 3.5s t90 = 8s |
6mm
t50 = 3.5s t90 = 8s |
Maximum process pressure : at 400ºC | 100 bar | dependent on thermowell | 100 bar |
Version | TR65 | TR66 |
Certification | ATEX EEx ia
ATEX EEx d |
ATEX EEx ia
ATEX EEx d |
Process connections | Thread (NPT)
flange (ANSI) |
Thread (NPT)
flange (ANSI) |
Sensor element diameter | 3mm, 4.5mm, 6mm, 8mm | 3mm, 6mm |
Response times (straight tip) | 6mm
t50 = 3.5s, t90 = 8s |
6mm
t50 = 3.5s, t90 = 8s |
Maximum process pressure : at 400ºC | 100 bar | 480 bar |
For more information, specific application advice or to order,
Please Contact us on +91 8367005552 or +91 9063008734
email: info@sigmaautomation.co.in or instsales@sigmaautomation.co.in
Please Contact us on +91 8367005552 or +91 9063008734For more information, specific application advice or to order,
Technical Information
Omnigrad S TR61
Omnigrad S TR62
Omnigrad S TR63
Omnigrad S TR65
Omnigrad S TR66