Temperature Measurement, Omnigrad S TC61/62/63/65/66

TC61

  • Oil & Gas processing industry
  • Measuring range: –40 to 1100 °C (–40 to 2012 °F)
  • Static pressure range up to 75 bar dependent on the used process connection

TC62

  • Oil & Gas processing industry
  • Measuring range: –40 to 1100 °C (–40 to 2 012 °F)
  • Static pressure range up to 100 bar dependent on the used process connection

TC63

  • Oil & Gas processing industry
  • Measuring range: –40 to 1100 °C (–40 to 2012 °F)
  • Static pressure range up to 100 bar dependent on the used process connection

TC65

  • Fine Chemicals, Petrochemical industry, Power stations, Environmental engineering
  • Measuring range: –40 to 1100 °C (–40 to 2 012 °F)
  • Static pressure range up to 75 bar dependent on the used process connection

TC66

  • Oil & Gas processing industry
  • Measuring range: –40 to 1 100 °C (–40 to 2 012 °F)
  • Static pressure range up to 100 bar (1450 psi)

Description

Thermocouple temperature sensor. Suitable for hazardous area use.

Omnigrad S temperature sensors which are specifically designed for these challenging applications. If bar stock thermowells, special materials and self-diagnosis field transmitters are considered the norm and you require a customised design or thermowell strength verification, then there is much to choose from within the Omnigrad S range.

The thermometers can be used in process industries such as:

  • Chemical industry
  • Energy industry
  • Gas processing industry
  • Petrochemical industry
  • General industrial services

Technical Data

Version TC61 TC62 TC63
Certification ATEX EEx ia

ATEX EEx d

ATEX EEx ia

ATEX EEx d

ATEX EEx ia

ATEX EEx d

Process connections Compression fitting, thread (NPT/G) or flange (ANSI/DIN) Thermowell thread: ½”NPT Compression fitting, thread (NPT/G) or flange (ANSI/DIN)
Sensor element diameter 3mm, 6mm 3mm, 6mm 3mm, 6mm
Response times t50 = 2.5s, t90 = 7s t50 = 2.5s, t90 = 7s t50 = 2.5s, t90 = 7s
Maximum process pressure : at 400ºC 100 bar dependent on thermowell 100 bar

 

Version TC65 TC66
Certification ATEX EEx ia

ATEX EEx d

ATEX EEx ia

ATEX EEx d

Process connections Thread (NPT)

flange (ANSI)

Thread (NPT)

flange (ANSI)

Sensor element diameter 3mm, 6mm 3mm, 6mm
Response times t50 = 2.5s, t90 = 7s t50 = 2.5s, t90 = 7s
Maximum process pressure : at 400ºC 80 bar 480 bar

For more information, specific application advice or to order, 

Please Contact us on +91 8367005552 or +91 9063008734

email: info@sigmaautomation.co.in or instsales@sigmaautomation.co.in
Please Contact us on +91 8367005552 or +91 9063008734For more information, specific application advice or to order,

Technical Information

Omnigrad S TC61

TI for Omnigrad S TC61

Omnigrad S TC62

TI for Omnigrad S TC62

Omnigrad S TC63

TI for Omnigrad S TC63

Omnigrad S TC65

TI for Omnigrad S TC65

Omnigrad S TC66

TI for Omnigrad S TC66