Point level detection, Solicap FTI55/56

FTI55

Temperature                     : -50 to +180°C

Pressure                              : -1 to +25bar

Measurement Range     : 200 to 4,000mm (4 to 157″)

FTI56

Temperature                     : -50 to +180°C

Pressure                              : -1 to +25bar

Measurement Range     : 500 to 22,000mm (20 to 866″)

Application

Point level detection for fine-grained to coarse-grained bulk solids

Description

Point level detection for fine-grained to coarse-grained bulk solids

The Solicap M compact transmitter offers reliable level limit detection in bulk solids. Available as a rod (FTI55) or rope (FTI56) version, it can be operated in minimum or maximum failsafe mode and is used for level limit detection in storage, buffer and process tanks and for two-point control. Due to its robust construction, it can also be used to provide accurate measurement in applications with very high tensile loads (up to 60kN for rope version) or lateral loads (up to 300Nm for rod version). In addition, the gastight probe seal prevents the effects of aggressive and toxic media and rough ambient conditions, such as strong vibration and increased temperatures, are overcome by separate electronics (up to 6m).

Solicap M is easily and quickly calibrated on site by simply pressing a button, facilitating quick and simple commissioning. An intelligent electronic memory (EEprom) saves instrument and calibration parameters so that all of the data is automatically transferred to the new electronics in case of an exchange. Time-consuming manual instrument calibration is unnecessary so downtime is kept to a minimum.

Technical Data FTI55 FTI56
Measured variable Capacitance change between probe and vessel wall Capacitance change between probe and vessel wall
Min capacitance change ≥ 5pF ≥ 5pF
Measuring frequency 500kHz 500kHz
Process Temperature -50…+180°C -50…+180°C
Pressure -1 to 25 bar -1 to 25 bar
Probe capacitance Rod: approx 1.3pF/100mm in air Rope: approx 1.0pF/100mm in air
Housing Aluminium, polyester or stainless steel Aluminium, polyester or stainless steel
Ambient temperature (housing) -50°C…+70°C -50°C…+70°C
Certification ATEX, FM, CSA, IEC Ex, JPN Ex, NEPSI ATEX, FM, CSA, IEC Ex, JPN Ex, NEPSI
Input signal Probe covered: high capacitance

Probe uncovered: low capacitance

Probe covered: high capacitance

Probe uncovered: low capacitance

Process connections Thread R1 1/2, NPT1 1/2

Flanges from DN50…/ASME 2″…/JIS…

Thread R1 1/2, NPT1 1/2

Flanges from DN50…/ASME 2″…/JIS…

Reproducibility 0.1% 0.1%