Prosonic FMU40

Process connection         : Thread

Temperature                     : -40 to +80°C

Pressure                              : +0.7 to +3bar

Blocking Distance             : Liquids and Solids 0.25m (0.8ft)

Maximum measuring distance: Liquids 5m (16ft), Solids 2m (16ft)

 

Prosonic FMU41

Process connection         : Thread

Temperature                     : -40 to +80°C

Pressure                              : +0.7 to +3bar

Blocking Distance             : Liquids and Solids 0.35m (1.15ft)

Maximum measuring distance: Liquids 8m (26ft), Solids 3.5m (11ft)

 

Prosonic FMU42

Process connection         : Flange

Temperature                     : -40 to +80°C (-40 to +176°F)

Pressure                              : +0.7 to +2.5bar (+10 to +36psi)

Blocking distance             : Liquids and Solids 0.4m (1.3ft)

Maximum measuring distance: Liquids 10m (33ft), Solids 5m (16ft)

 

Prosonic FMU43

Process connection         : Flange

Temperature                     : -40 to +80°C

Pressure                              : +0.7 to +2.5bar

Blocking distance             : Liquids and Solids 0.6m (2ft)

Maximum measuring distance: Liquids 15m (50ft), Solids 7m (23ft)

 

Prosonic FMU44

Process connection         : Flange

Temperature                     : -40 to +80°C

Pressure                              : +0.7 to +2.5bar

Blocking distance             : Liquids and Solids 0.5m (1.9ft)

Maximum measuring distance: Liquids 20m (66ft), Solids 10m (33ft)

Description

Non-contact Ultrasonic Level Measurement for liquids and solids using the Time of Flight principle.

Prosonic M is both compact and reliable, providing continuous, non-contact level measurement in both liquids and bulk solids. For liquid level measurement, Prosonic is ideal for continuous monitoring of water and waste levels, with the whole instrument tested to IP68/ NEMA 6P standards. In bulk solids applications, Prosonic provides reliable measurement in controlled monitoring of silo levels, conveyer transfer stations and hoppers.

Prosonic M is robust, cost-effective and versatile. It can be used for flow measurement in open channels and weirs and in conjunction with our RMA42 display (see Recorders & System Components section), Prosonic M is a cost-effective solution for both screen and pump control.

Available in both 2 and 4-wire versions, Prosonic M features an integrated temperature sensor for Time of Flight correction so that measurement is accurate, even with temperature changes. Prosonic M has a 4-line menu-driven display and comes with free Fieldcare Device Setup software for simple commissioning, maintenance, diagnosis and documentation of the measuring point.

Technical Data

Process temperature -40°C…+80°C
Protection Closed housing: IP68, NEMA 6P (24h at 1.83m under water surface)
Process pressure 3 bar abs (FMU40/41), 2.5 bar abs (FMU42/43)
Certification ATEX II 1/2 G and ATEX II 1/3 D
Process connection G1½” BSP thread (FMU40), G2” BSP thread (FMU41)

DN80/DN100 universal slip-on flange (FMU42/43) + DN150 (FMU44)

Wetted parts PVDF/EPDM (FMU40/41), UP and VA stainless steel 316Ti (FMU43)
Power supply 2-wire 4…20mA loop powered, 4-wire AC/DC,

PROFIBUS PA, FOUNDATION Fieldbus

Measuring range 5m in liquids/2m in solids (FMU40), 8m in liquids/3.5m in solids (FMU41)

10m in liquids/5m in solids (FMU42), 15m in liquids/7m in solids (FMU43)

20m in liquids/10m in solids (FMU44)

For more information, specific application advice or to order,

Please Contact us on +91 8367005552 or +91 9063008734

email: info@sigmaautomation.co.in or instsales@sigmaautomation.co.in

Technical Information

Deltapilot FMU40/41/42/43/44

TI FOR FMU40_41_42_43_44