Level Measurement, Levelflex FMP51/52/54

FMD51

  • Temperature: -20 to +150°C (-4 to +302°F)
  • Pressure: -1 to +16bar (-14.5 to +232psi)
  • Maximum measuring range: Rod 6m (20ft)
  • Accuracy: ±2mm (0.12″)

FMD52

  • Temperature: -50 to +200°C (-58 to +392°F)
  • Pressure: -1 to +40bar (-14.5 to +580psi)
  • Maximum measuring range: Rod 4m (13ft), rope 45m (148ft)
  • Accuracy: Rod probe ±2mm (0.08″)

FMD54

  • Temperature: -196 to +450°C (-320 to +842°F)
  • Pressure: -1 to +400bar (-14.5 to +5,800psi)
  • Maximum measuring range: Rod 10m (33ft), rope 45m (148ft), coax 6m (20ft)
  • Accuracy: rod ±2mm (0.08″)

Description

Guided wave radar level measurement in liquids and solids.

For use across industry With a choice of sensors (rod, coaxial or rope) covering liquids, solids, pastes, liquefied gases or bulk solids, exactly the right model can be selected for a variety of industrial applications including chemical, cement, food, life science and hydrocarbon processing. Severe conditions are not a problem as the sensors handle low/high pressures (vacuum up to 400 bar), low/high temperatures (-200°C up to +450°C) and corrosive or abrasive materials.

Multi-echo tracking

Developed to allow for a more reliable measurement by utilising multiple echoes to track obstacles accurately within a vessel, the software combines increased echo rate and analysis with the automatic suppression of interfering echoes. Dynamic, continuously adapting evaluation algorithms guarantee precise measurement results.

Technical data FMP51 FMP52 FMP54
Process media Liquids Liquids Liquids
Measuring range Up to 45m Up to 45m Up to 45m
Output 4…20mA, HART, PROFIBUS PA, switch 4…20mA, HART, PROFIBUS PA, switch 4…20mA, HART, PROFIBUS PA, switch
Power supply 2-wire; 4…20mA loop, 4-wire 90…253V AC, 4-wire 10.4…48V DC 2-wire; 4…20mA loop, 4-wire 90…253V AC, 4-wire 10.4…48V DC 2-wire; 4…20mA loop, 4-wire 90…253V AC, 4-wire 10.4…48V DC
Temperature -40…+200°C -50…+200°C -196…+450°C
Pressure -1…+40 bar -1…+40 bar -1…+400 bar
Certification ATEX, CSA, IEC Ex ATEX, CSA, IEC Ex ATEX, CSA, IEC Ex
Protection IP68 IP68 IP68