Electromagnetic Flowmeter, Promag 300/500

Measured variables and Range

  • Volume flow, conductivity, mass flow
  • Range, H-300 – 0.06 dm³/min to 600 m³/h, P-300/500 – 4 dm³/min to 9600 m³/h

Max. Measurement error

  • Volume flow (standard): ±0.5 % or ± 1 mm/s (0.04 in/s)
  • Volume flow (option): ±0.2 % or ± 2 mm/s (0.08 in/s)

Max. Process Pressure

  • PN 40, Class 300, 20K

Medium temperature range

P-300/500

  • Liner material PFA: –20 to +150 °C (–4 to +302 °F)
  • Liner material PFA high-temperature: –20 to +180 °C (–4 to +356 °F)
  • Liner material PTFE: –40 to +130 °C (–40 to +266 °F)

H-300

  • –20 to +150 °C (–4 to +302 °F)

Application

  • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
  • P-300, Dedicated to chemical and process applications with corrosive liquids and high medium temperatures
  • H-300, Dedicated to demanding applications in the food and beverage as well as in life sciences industries
  • P-500, Dedicated to chemical and process applications with corrosive liquids and high medium temperatures

Description

Electromagnetic flowmeters with unsurpassed measuring performance under real process conditions.

Promag 300 (compact housing) and Promag 500 (remote housing) make no compromise in measuring performance and accuracy. Digital signal processing starts right at the intelligent sensor and is the base for a truly multi-parameter measuring device. Process values such as mass flow, volume flow and conductivity can be measured with one single sensor. Offering a large variety of digital communication protocols including EtherNet/IP, Modbus RS485, PROFIBUS DP/PA, ProfiNet, FOUNDATION Fieldbus, HART and WirelessHART as well as fully freely configurable analogue outputs Promag 300/500 fulfils all expectation for a seamless system integration.

Technical data H sensor P sensor
Version For the smallest flow quantities and demanding hygienic applications Meets the highest requirements for the process industry
Measured variables Direct: volume flow, electrical conductivity, temperature (DN15…150).

Calculated: mass flow, corrected volume flow, corrected electrical conductivity

Direct: volume flow, electrical conductivity.

Calculated: mass flow, corrected volume flow.

Nominal diameter DN2…150 DN15…600
Liner PFA (USP Class VI, FDA 21 CFR 177.1550, 3-A) PFA, PTFE
Housing Stainless steel 1.4301 Coated aluminium or stainless steel
Process connection Hygienic clamp, thread. Standard thread, flange Flange
Medium temperature -20…+150°C -40…+180°C
Hazardous area ATEX, IECEx, cCSAu ATEX, IECEx, cCSAu
Protection IP68 IP66/67, type 4X enclosure
Approvals 3-A approval and EHEDG-certified with FDAcompliant seals (excludes Kalrez) N. A

 

Technical data W sensor
Version For demanding applications in the water & wastewater industry
Measured variables Direct: volume flow, electrical conductivity. Calculated: mass flow.
Nominal diameter DN25…2000
Liner Polyurethane, hard rubber
Housing Coated aluminium or plastic
Process connection Flange
Medium temperature -20…+80°C
Hazardous area ATEX, IECEx, cCSAu
Protection IP66/67, type 4X enclosure
Approvals WRAS BS6920 drinking water

Promag H-300 properties

  • H-300, Liner made of PFA
  • Sensor housing made of stainless steel (3A, EHEDG)
  • Wetted materials CIP, SIP cleanable
  • Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os
  • Backlit display with touch control and WLAN access

Promag P-300/500 properties

  • Nominal diameter: max. DN 600 (24″)
  • All common Ex approvals
  • P-300/500 Liner made of PTFE or PFA
  • Compact dual-compartment housing with up to 3 I/Os
  • Backlit display with touch control and WLAN access
  • Remote display available
  • P-300, Remote version with up to 4 I/Os
  • P-500, Standard cable between sensor and transmitter

For more information, specific application advice or to order, 

Please Contact us on +91 8367005552 or +91 9063008734

email: info@sigmaautomation.co.in or instsales@sigmaautomation.co.in
Please Contact us on +91 8367005552 or +91 9063008734For more information, specific application advice or to order,

Technical Information

Promag H-300

TI for Promag H-300

Promag P-300

TI for Promag P-300

Promag P-500

TI for Promag P-500